ucs_lan_connectivity – Configures LAN Connectivity Policies on Cisco UCS Manager

From Get docs
Ansible/docs/2.7/modules/ucs lan connectivity module


ucs_lan_connectivity – Configures LAN Connectivity Policies on Cisco UCS Manager

New in version 2.5.


Synopsis

Requirements

The below requirements are needed on the host that executes this module.

  • ucsmsdk

Parameters

Parameter Choices/Defaults Comments

description

-

A description of the LAN Connectivity Policy.

Cisco recommends including information about where and when to use the policy.

Enter up to 256 characters.

You can use any characters or spaces except the following:

` (accent mark), (backslash), ^ (carat), " (double quote), = (equal sign), > (greater than), < (less than), or ' (single quote).


aliases: descr

hostname

string / required

IP address or hostname of Cisco UCS Manager.

name

- / required

The name of the LAN Connectivity Policy.

This name can be between 1 and 16 alphanumeric characters.

You cannot use spaces or any special characters other than - (hyphen), "_" (underscore), : (colon), and . (period).

You cannot change this name after the policy is created.

org_dn

-

Default:

"org-root"

Org dn (distinguished name)

password

string / required

Password for Cisco UCS Manager authentication.

port

integer

Port number to be used during connection (by default uses 443 for https and 80 for http connection).

proxy

string

If use_proxy is no, specfies proxy to be used for connection. e.g. 'http://proxy.xy.z:8080'

state

-

  • present

  • absent

If present, will verify LAN Connectivity Policies are present and will create if needed.

If absent, will verify LAN Connectivity Policies are absent and will delete if needed.

use_proxy

boolean

  • no
  • yes

If no, will not use the proxy as defined by system environment variable.

use_ssl

boolean

  • no
  • yes

If no, an HTTP connection will be used instead of the default HTTPS connection.

username

string

Default:

"admin"

Username for Cisco UCS Manager authentication.

vnic_list

-

List of vNICs used by the LAN Connectivity Policy.

vNICs used by the LAN Connectivity Policy must be created from a vNIC template.

Each list element has the following suboptions:

= name

The name of the vNIC (required).

= vnic_template

The name of the vNIC template (required).

- adapter_policy

The name of the Ethernet adapter policy.

A user defined policy can be used, or one of the system defined policies.

- order

String specifying the vNIC assignment order (e.g., '1', '2').

[Default: unspecified]



Examples

- name: Configure LAN Connectivity Policy
  ucs_lan_connectivity:
    hostname: 172.16.143.150
    username: admin
    password: password
    name: Cntr-LAN-Boot
    vnic_list:
    - name: Fabric-A
      vnic_template: vNIC-Template-A
      adapter_policy: Linux
    - name: Fabric-B
      vnic_template: vNIC-Template-B
      adapter_policy: Linux

- name: Remove LAN Connectivity Policy
  ucs_lan_connectivity:
    hostname: 172.16.143.150
    username: admin
    password: password
    name: Cntr-LAN-Boot
    state: absent

Status

Authors

  • David Soper (@dsoper2)