f5networks.f5_modules.bigip_monitor_ftp – Manage FTP monitors on a BIG-IP

From Get docs
Ansible/docs/2.11/collections/f5networks/f5 modules/bigip monitor ftp module


f5networks.f5_modules.bigip_monitor_ftp – Manage FTP monitors on a BIG-IP

Note

This plugin is part of the f5networks.f5_modules collection (version 1.7.1).

To install it use: ansible-galaxy collection install f5networks.f5_modules.

To use it in a playbook, specify: f5networks.f5_modules.bigip_monitor_ftp.


New in version 1.1.0: of f5networks.f5_modules


Synopsis

  • Manage FTP monitors on a BIG-IP device.

Parameters

Parameter Choices/Defaults Comments

app_service

string

The iApp service to be associated with this profile. When no service is specified, the default is None.

debug

boolean

  • no
  • yes

Specifies whether the monitor sends error messages and additional information to a log file created and labeled specifically for this monitor.

When yes the system redirects error messages and additional information to the /var/log/monitors/<monitor_name>-<node_name>-<port>.log file.

description

string

The description of the monitor.

filename

string

Specifies the full path and file name of the file the system attempts to download. The health check is successful if the system can download the file.

interval

integer

The interval specifying how frequently the monitor instance of this template will run.

This value must be less than the timeout value.

When creating a new monitor, if this parameter is not provided, the default 5 will be used.

ip

string

IP address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'.

manual_resume

boolean

  • no
  • yes

Specifies whether the system automatically changes the status of a resource to enabled at the next successful monitor check.

If you set this option to yes, you must manually re-enable the resource before the system can use it for load balancing connections.

When creating a new monitor, if this parameter is not specified, the default value is no.

When yes, specifies you must manually re-enable the resource after an unsuccessful monitor check.

When no, specifies the system automatically changes the status of a resource to enabled at the next successful monitor check.

mode

string

  • passive
  • port

Specifies the data transfer process (DTP) mode.

When passive, the monitor sends a data transfer request to the FTP server. When the FTP server receives the request, the FTP server initiates and establishes the data connection.

When port, the monitor initiates and establishes the data connection with the FTP server.

name

string / required

Specifies the name of the monitor.

parent

string

The parent template of this monitor template. Once this value has been set, it cannot be changed.

When creating a new monitor, if this parameter is not specified, the default is the system-supplied ftp monitor.

partition

string

Default:

"Common"

Device partition to manage resources on.

port

string

Port address part of the IP/port definition. If this parameter is not provided when creating a new monitor, the default value is '*'. If specifying an IP address, you must use a value between 1 and 65535.

provider

dictionary

added in 1.0.0 of f5networks.f5_modules

A dict object containing connection details.

auth_provider

string

Configures the auth provider for to obtain authentication tokens from the remote device.

This option is really used when working with BIG-IQ devices.

no_f5_teem

boolean

  • no
  • yes

If yes, TEEM telemetry data is not sent to F5.

You may omit this option by setting the environment variable F5_TEEM.

password

string / required

The password for the user account used to connect to the BIG-IP.

You may omit this option by setting the environment variable F5_PASSWORD.


aliases: pass, pwd

server

string / required

The BIG-IP host.

You may omit this option by setting the environment variable F5_SERVER.

server_port

integer

Default:

443

The BIG-IP server port.

You may omit this option by setting the environment variable F5_SERVER_PORT.

timeout

integer

Specifies the timeout in seconds for communicating with the network device for either connecting or sending commands. If the timeout is exceeded before the operation is completed, the module will error.

transport

string

  • rest

Configures the transport connection to use when connecting to the remote device.

user

string / required

The username to connect to the BIG-IP with. This user must have administrative privileges on the device.

You may omit this option by setting the environment variable F5_USER.

validate_certs

boolean

  • no
  • yes

If no, SSL certificates are not validated. Use this only on personally controlled sites using self-signed certificates.

You may omit this option by setting the environment variable F5_VALIDATE_CERTS.

state

string

  • present

  • absent

When present, ensures the monitor exists.

When absent, ensures the monitor is removed.

target_password

string

Specifies the password, if the monitored target requires authentication.

target_username

string

Specifies the user name, if the monitored target requires authentication.

time_until_up

integer

Specifies the amount of time in seconds after the first successful response before a node will be marked up.

A value of 0 will cause a node to be marked up immediately after a valid response is received from the node.

If this parameter is not provided when creating a new monitor, then the default value will be 0.

timeout

integer

The number of seconds in which the node or service must respond to the monitor request.

If the target responds within the set time period, it is considered up.

If the target does not respond within the set time period, it is considered down.

You can change this to any number, however, it should be 3 times the interval number of seconds plus 1 second.

If this parameter is not provided when creating a new monitor, then the default value will be 31.

up_interval

integer

Specifies the interval at which the system performs the health check when a resource is up.

When 0, specifies the system uses the interval specified in interval to check the health of the resource.

When any other number, enables you to specify a different interval to use when checking the health of a resource that is up.

When creating a new monitor, if this parameter is not provided, the default 0 will be used.

update_password

string

  • always

  • on_create

always will update passwords if the target_password is specified.

on_create will only set the password for newly created monitors.



Notes

Note

  • For more information on using Ansible to manage F5 Networks devices see https://www.ansible.com/integrations/networks/f5.
  • Requires BIG-IP software version >= 12.
  • The F5 modules only manipulate the running configuration of the F5 product. To ensure that BIG-IP specific configuration persists to disk, be sure to include at least one task that uses the f5networks.f5_modules.bigip_config module to save the running configuration. Refer to the module’s documentation for the correct usage of the module to save your running configuration.


Examples

- name: Create FTP Monitor
  bigip_monitor_ftp:
    state: present
    ip: 10.10.10.10
    name: my_ft_monitor
    provider:
      server: lb.mydomain.com
      user: admin
      password: secret
  delegate_to: localhost

- name: Remove FTP Monitor
  bigip_monitor_ftp:
    state: absent
    name: my_ftp_monitor
    provider:
      server: lb.mydomain.com
      user: admin
      password: secret
  delegate_to: localhost

- name: Include a username and password in the FTP monitor
  bigip_monitor_ftp:
    state: absent
    name: my_ftp_monitor
    target_username: monitor_user
    target_password: monitor_pass
    provider:
      server: lb.mydomain.com
      user: admin
      password: secret
  delegate_to: localhost

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description

app_service

string

changed

The iApp service associated with this monitor.


Sample:

/Common/good_service.app/good_service

debug

boolean

changed

Whether the monitor sends error messages and additional information to a log file created and labeled specifically for this monitor.


description

string

changed

The description of the monitor.


Sample:

Important Monitor

filename

string

changed

Specifies the full path and file name of the file the system attempts to download.


Sample:

/ftp/var/health.txt

interval

integer

changed

The new interval at which to run the monitor check.


Sample:

2

ip

string

changed

The new IP of IP/port definition.


Sample:

10.12.13.14

manual_resume

boolean

changed

Specifies whether the system automatically changes the status of a resource to up at the next successful monitor check.


Sample:

True

mode

string

changed

Specifies the data transfer process (DTP) mode.


Sample:

passive

parent

string

changed

The parent monitor.


Sample:

/Common/foo_ftp

port

string

changed

Alias port or service for the monitor to check, on behalf of the pools or pool members with which the monitor is associated.


Sample:

80

time_until_up

integer

changed

The new time in which to mark a system as up after first successful response.


Sample:

2

timeout

integer

changed

The new timeout in which the remote system must respond to the monitor.


Sample:

10

up_interval

integer

changed

Interval for the system to use to perform the health check when a resource is up.





Authors

  • Wojciech Wypior (@wojtek0806)

© 2012–2018 Michael DeHaan
© 2018–2021 Red Hat, Inc.
Licensed under the GNU General Public License version 3.
https://docs.ansible.com/ansible/2.11/collections/f5networks/f5_modules/bigip_monitor_ftp_module.html