Synopsis

  • This module provides declarative management of VLANs on Ubiquiti Edgeswitch network devices.

Parameters

Parameter Choices/Defaults Comments

aggregate

-

List of VLANs definitions.

auto_exclude

boolean

  • no
  • yes

Each of the switch interfaces will be excluded from vlan_id unless defined in *_interfaces. This is a default setting for all switch interfaces.

auto_tag

boolean

  • no
  • yes

Each of the switch interfaces will be set to accept and transmit untagged frames for vlan_id unless defined in *_interfaces. This is a default setting for all switch interfaces.

auto_untag

boolean

  • no
  • yes

Each of the switch interfaces will be set to accept untagged frames and transmit them tagged for vlan_id unless defined in *_interfaces. This is a default setting for all switch interfaces.

excluded_interfaces

-

List of interfaces that should be excluded of the VLAN. Accept range of interfaces.

name

-

Name of the VLAN.

purge

boolean

  • no

  • yes

Purge VLANs not defined in the aggregate parameter.

state

-

  • present

  • absent

action on the VLAN configuration.

tagged_interfaces

-

List of interfaces that should accept and transmit tagged frames for the VLAN. Accept range of interfaces.

untagged_interfaces

-

List of interfaces that should accept untagged frames and transmit them tagged for the VLAN. Accept range of interfaces.

vlan_id

-

ID of the VLAN. Range 1-4093.



Notes

Note

  • Tested against edgeswitch 1.7.4
  • This module use native Ubiquiti vlan syntax and does not support switchport compatibility syntax. For clarity, it is strongly advised to not use both syntaxes on the same interface.
  • Edgeswitch does not support deleting or changing name of VLAN 1
  • As auto_tag, auto_untag and auto_exclude are a kind of default setting for all interfaces, they are mutually exclusive


Examples

- name: Create vlan
  edgeswitch_vlan:
    vlan_id: 100
    name: voice
    action: present

- name: Add interfaces to VLAN
  edgeswitch_vlan:
    vlan_id: 100
    tagged_interfaces:
      - 0/1
      - 0/4-0/6

- name: setup three vlans and delete the rest
  edgeswitch_vlan:
    purge: true
    aggregate:
      - { vlan_id: 1, name: default, auto_untag: true, excluded_interfaces: 0/45-0/48 }
      - { vlan_id: 100, name: voice, auto_tag: true }
      - { vlan_id: 200, name: video, auto_exclude: true, untagged_interfaces: 0/45-0/48, tagged_interfaces: 0/49 }

- name: Delete vlan
  edgeswitch_vlan:
    vlan_id: 100
    state: absent

Return Values

Common return values are documented here, the following are the fields unique to this module:

Key Returned Description

commands

list

always

The list of configuration mode commands to send to the device


Sample:

['vlan database', 'vlan 100', 'vlan name 100 "test vlan"', 'exit', 'interface 0/1', 'vlan pvid 50', 'vlan participation include 50,100', 'vlan tagging 100', 'vlan participation exclude 200', 'no vlan tagging 200']